External Wall Insulation 3

Features & Benefits

• Suitable for must substrates types including steel

   framing systems with infill panels

• The System can be finished In a range of textures and

   over 200 vibrant colours

• Increases the thermal performance of buildings without

   reducing interior space

• Insulation with low thermal conductivity allow for thinner

   insulation boards to be used or higher U-values to be

   achieved

• System requires minimum maintenance

 

 

 

About

Typical System Build Up

Technical Downloads

System 3 Applications

 

• Primarily used in the refurbishment of existing dwellings/structures

• System 3 can be applied over solid masonry, concrete panels, no fines concrete and masonry with cavity

• The system is also suitable for installation over non-traditional house types (See Enewall’s technical

   services

 

System 1 has also been successfully installed on non- traditional house types such as Wimpey no fines

and Orlit.

 

Enhanced Life Expectancy

The systems life expectancy is no less than 30 years it can be extended to 60 years provided a planned inspection, maintenance programme is introduced and certain system components are used in accordance with section 12 and 13 of Enewall’s BBA Agrement certificate (13/4973) .

 

Design Considerations

Before your walls can be insulated, any problems with penetrating or rising damp must be resolved. Insulation should not be used to cover, hide or isolate damp as this could lead to serious problems in the future.

 

Before/After the installation of an Enewall system, visual inspections of architectural details designed to shed water should be made, to confirm that they are performing correctly. This is to ensure water is not leaking from external downpipes or gutters, such leakage could have a detrimental effect on the system.

 

Fire Performance

Fire barriers are required between all compartments in all buildings of differing occupancy and to prevent the spread of fire in multi-storey single occupancy buildings.

 

Continuous horizontal firebreaks are required on every building above three storeys; barriers should be formed after the 2nd storey / beginning of 3rd storey, and every storey thereafter.

 

In England, Wales and Northern Ireland any system comprising of Grey EPS,PIR and Phenolic may be use up to 18m and within any distance from  a boundary. In Scotland any system comprising of Grey EPS, PIR and Phenolic may be used up to 18m however it must not be used within 1m of the boundary .

 



Technical Services
Planning Stage

Enewall’s architects and technical advisors are available to give advice at the planning stage ensuring the correct system is specified, U-value and condensations risk analysis can be prepared on request.

 

Design

Detailed specifications and cad drawings can be prepared for individual projects.

 

On Site Support

Sit visits, on site demonstrations and training can be arranged on request.

 

For any technical enquiries please call Enewall main office on 01698 373 305 or via email technical@enewall.co.uk

• System Starter Track

• Insulation-Adhesively  or Mechanically Fix Board

• Adhesive

• Reinforcement Mesh

• Adhesive

• Primer

• Acrylic Finish